What the refrigerant phase-down means if you own — or are buying — a home with central air
If you’re buying a home in South Jersey, there’s a good chance the air conditioner or heat pump uses R-410A refrigerant, sometimes labeled “Puron.” With the refrigerant changes of the last couple of years, I get a lot of questions about it. Here’s what homeowners need to know.
Is R-410A banned?
Not for existing systems. Under the federal AIM Act, the EPA stopped the manufacture and import of new residential split air conditioning and heat pump systems that use R-410A starting January 1, 2025. New systems now use lower-impact refrigerants such as R-454B and R-32.
What that means for you:
- You don’t have to replace a working R-410A system. Existing systems are legal to keep and operate.
- They can still be serviced and repaired. R-410A refrigerant remains available for maintenance, although production is being reduced each year, so prices may rise over time.
- Older inventory can still be installed. Under a 2026 rule update, R-410A units made or imported before January 1, 2025 can still be installed until supplies run out.
Why the change?
R-410A replaced the older R-22 (“Freon”) because R-22 damaged the ozone layer. R-410A is ozone-safe, but it is a powerful greenhouse gas when it leaks: its global warming potential is roughly 2,088 times that of carbon dioxide. The newer refrigerants are far lower, and federal rules now cap the refrigerant used in new residential systems.
Were R-410A systems unreliable?
You may have heard that R-410A equipment didn’t hold up. The refrigerant runs at higher pressures than R-22, and manufacturers built the equipment to handle it with heavier compressors, tubing and joints. Most of the problems people experienced came from how systems were installed and serviced:
- Moisture in the lines. R-410A systems use a synthetic oil that absorbs moisture. If the installer doesn’t pull a proper deep vacuum, moisture mixes with the oil and forms acids that damage the compressor.
- Debris from brazing. Joints brazed without flowing nitrogen through the lines leave flakes of copper oxide inside, which can clog valves and damage the compressor.
- Charging by “feel.” These systems need an accurate charge measured with gauges and temperature readings, not guesswork.
- Coil corrosion. Thinner, high-efficiency indoor coils from this era were prone to tiny pinhole leaks caused by household chemicals reacting with moisture on the coil.
A well-installed, well-maintained R-410A system can give many years of service. Installation quality matters as much as the equipment.
What I look at during an inspection
- The age, refrigerant type and data plate of the outdoor and indoor units
- Signs of oil residue or leaks at fittings and the indoor coil
- Temperature difference between supply and return air
- Condensate drainage, filters, and the condition of refrigerant line insulation
If the system is older or showing signs of trouble, it’s worth budgeting for replacement — and understanding that the new equipment will use a different refrigerant.